Epoxy Cast Dry-Type Transformer
SCB10, SCB11

Epoxy Cast Dry-Type Transformer

SCB10, SCB11 has a wide range of applications and is particularly suitable for places with high fire protection requirements, such as mines, oil fields, subways, power plants, schools, hospitals, commercial centers, high-rise buildings, and all indoor power distribution systems.

GET IN TOUCH
Key Features

Core

High-permeability grain-oriented silicon steel, 45° fully mitered stepped joints, square tube pull-plate structure, resin-coated for moisture/rust protection – low loss, low noise.

Safe & Eco-friendly

Non-combustible, fire-resistant, pollution-free – can be installed at load center.

Maintenance-free

Easy installation, low overall operating cost.

High moisture resistance

Operates normally at 100% humidity – no pre-drying required after shutdown.

Strong heat dissipation

Complete temperature protection control system – over-temperature alarm and trip functions.

Foil winding

Continuous copper foil winding, Class F insulation, resin-potted ends – solves short-circuit stress, ampere-turn imbalance, and poor heat dissipation.

High reliability: Proven reliability reaching international advanced level.

Technical Specifications

Operating Conditions

 

Installation altitude: Not exceeding 1000m above sea level;

Power supply voltage waveform: Approximately sinusoidal;

Symmetry of polyphase supply voltage: The supply voltage connected to the polyphase transformer shall be approximately symmetrical;

Ambient temperature: Maximum temperature +40℃; maximum daily average temperature +30℃; maximum annual average temperature +20℃; minimum temperature -30℃ (applicable to indoor transformers).

 

 

Epoxy Cast Dry-Type Transformer SCB10, SCB11

Rated Capacity (kVA) Voltage Combination & Tapping Range Connection Symbol Losses (120°C, kW) No-Load Current (%) Short-Circuit Impedance (%) Weight (kg)
HV (kV) HV Tapping Range (%) LV (kV) No-Load Loss (W) Load Loss (W) % Oil weight Total Weight
30

6
6.3
6.6
10
10.5
11

∓5%
∓2x2.5%
0.4 Yyn0
Dyn11
0.71 0.19 1.6 4 250 320
50 1 0.27 1.4 370 460
63 1.38 0.37 1.2 460 550
80 1.57 0.4 1.1 490 580
100 1.85 0.47 1.0 570 680
125 2.13 0.54 1.0 640 750
160 2.52 0.62 0.9 775 890
200 2.75 0.72 0.8 895 1030
250 3.47 0.88 0.8 1100 1250
315 3.99 0.98 0.7 1200 1350
400 4.88 1.16 0.7 1460 1610
500 5.87 1.34 0.6 1680 1840
630 5.96 1.3 0.6 6 1800 1980
800 6.95 1.52 0.5 2130 2310
1000 8.13 1.77 0.45 2520 2720
1250 9.69 2.09 0.45 3075 3300
1600 11.73 2.45 0.45 3670 3900
2000 14.45 3.32 0.4 4420 4670
2500 17.17 4 0.4 5310 5580
CONNECT WITH OUR EXPERTS
Access Fuyi's technical documentation and FAQs to help you quickly
select the right model and install with confidence.
  • Engineering Support – Drawing review, material selection, design optimization
  • Technical Guidance – Product selection, compatibility checking, application advice
  • Fast Response – 24-hour reply to your inquiries, samples in 7-15 days
GET IN TOUCH NOW
Captcha Code